TY - JOUR
T1 - The prevalence of the failure of fixed orthodontic bonded retainers: a systematic review and meta-analysis
AU - Aye, Su Thae
AU - Liu, Shiyao
AU - Byrne, Emer
AU - El-Angbawi, Ahmed
PY - 2023/12/1
Y1 - 2023/12/1
N2 - Objectives: To systematically assess the scientific literature for the prevalence of failure rate of fixed orthodontic bonded retainer (FOBR). Method: Randomized clinical trials (RCTs) and prospective non-RCTs involving participants who had FOBR fitted were included. The Cochrane Central Register of Controlled Trials, Web of science, MEDLINE, and EMBASE via OVID were searched from inception to January 2023. Risk of bias was assessed using the Cochrane RoB 2 and Newcastle-Ottawa tools. The main outcome was the failure rate of FOBRs. The secondary outcome was to identify factors that can influence the failure of FOBR. Meta-analyses and sensitivity analyses were undertaken using Revman, version5.4. A random-effects model was used. Quality assessment using Grading of Recommendations Assessment, Development, and Evaluation. Results: Thirty-four studies (25 RCTs and 9 prospective clinical studies) (3484 participants) were included in this review. The overall failure rate of bonded retainers, after excluding high-risk studies, was 35.22% (95% confidence interval [CI] 27.46-42.98). The failure rate is increased with the duration of follow up; with short-term follow-up rate 24.18% (95% CI 20.16-28.21), medium-term follow up 40.09% (95% CI 30.92-49.26), and long-term follow up 53.85% (95% CI 40.31-67.39). There is a low level of evidence to suggest there is no statistically significant difference in the failure rate of fixed retainers using direct versus indirect bonding methods, using liquid resin versus without liquid resin, and fibre-reinforced composite retainers compared to multi-stranded stainless steel retainers. Discussion: There is low-quality evidence to suggest that the failure rate of FOBR is relatively high. There is a need for high-quality, well-reported clinical studies to assess factors that can influence the failure rate of FOBR. Registration: CRD42021190910.
AB - Objectives: To systematically assess the scientific literature for the prevalence of failure rate of fixed orthodontic bonded retainer (FOBR). Method: Randomized clinical trials (RCTs) and prospective non-RCTs involving participants who had FOBR fitted were included. The Cochrane Central Register of Controlled Trials, Web of science, MEDLINE, and EMBASE via OVID were searched from inception to January 2023. Risk of bias was assessed using the Cochrane RoB 2 and Newcastle-Ottawa tools. The main outcome was the failure rate of FOBRs. The secondary outcome was to identify factors that can influence the failure of FOBR. Meta-analyses and sensitivity analyses were undertaken using Revman, version5.4. A random-effects model was used. Quality assessment using Grading of Recommendations Assessment, Development, and Evaluation. Results: Thirty-four studies (25 RCTs and 9 prospective clinical studies) (3484 participants) were included in this review. The overall failure rate of bonded retainers, after excluding high-risk studies, was 35.22% (95% confidence interval [CI] 27.46-42.98). The failure rate is increased with the duration of follow up; with short-term follow-up rate 24.18% (95% CI 20.16-28.21), medium-term follow up 40.09% (95% CI 30.92-49.26), and long-term follow up 53.85% (95% CI 40.31-67.39). There is a low level of evidence to suggest there is no statistically significant difference in the failure rate of fixed retainers using direct versus indirect bonding methods, using liquid resin versus without liquid resin, and fibre-reinforced composite retainers compared to multi-stranded stainless steel retainers. Discussion: There is low-quality evidence to suggest that the failure rate of FOBR is relatively high. There is a need for high-quality, well-reported clinical studies to assess factors that can influence the failure rate of FOBR. Registration: CRD42021190910.
KW - Humans
KW - Orthodontic Appliances, Fixed
KW - Orthodontic Retainers
KW - Prevalence
KW - Prospective Studies
KW - Stainless Steel
UR - https://www.scopus.com/pages/publications/85178498609
UR - https://www.mendeley.com/catalogue/51f09de9-72b0-3842-9dd5-8abe10326605/
U2 - 10.1093/ejo/cjad047
DO - 10.1093/ejo/cjad047
M3 - Article
C2 - 37824794
SN - 0141-5387
VL - 45
SP - 645
EP - 661
JO - European Journal of Orthodontics
JF - European Journal of Orthodontics
IS - 6
ER -